Mold temperature controllers come in two families: water type, which circulates heated or cooled water through the mould, and oil type, which circulates heated thermal oil. Both hold a mould at a precise, stable temperature. The right one depends on the temperature you need, the material you mould, and how much you care about contamination and energy cost.
A water type unit has an integral stainless steel tank, a heater, and a pump that pushes water through the mould circuit. Some models can also cool, giving a single unit that handles both heating and cooling across a wide band.
An oil type unit uses a heated oil reservoir and a high temperature pump to push hot oil through the mould. Because oil degrades slowly at temperature and does not evaporate, it reaches and holds very high temperatures reliably.
| System | Typical range | Notes |
|---|---|---|
| Water type | up to 90–120 °C heating; cooling down to 5–10 °C on combination units | Boiling point is the hard limit; pressure must be managed |
| Oil type | up to 200–350 °C | Special high temperature units reach 300 °C+ |
| Combination / dual temperature | −20 to 120 °C | One unit replaces a chiller plus a heater |
Standard water type units reach about 90 °C, which covers PP, ABS, PA, PC and most engineering plastics. Above 120 °C you need either a pressurised water system or oil. Zillion's 300 °C high temperature precision MTC covers the extreme end, and the dual temperature integrated MTC handles combined heating and cooling in one cabinet.
This is where the choice becomes obvious rather than a matter of preference.
Typical units: the 6 kW PID water MTC and 9 kW water heating MTC.
Typical units: the 12 kW oil type MTC, 24 kW oil MTC and 36 kW oil MTC.
| Factor | Water type | Oil type |
|---|---|---|
| Heating energy cost | Lower | Higher — larger thermal mass |
| Warm-up and changeover time | Faster | Slower |
| Contamination risk | Very low | Oil residue on colour change |
| Max temperature | 90–120 °C standard | 200–350 °C |
| Maintenance | Scale, pump seal | Oil analysis, oxidation, pump seal |
| Heat loss to ambient | Lower | Higher over a long pipe run |
Many moulding shops run two different polymers on the same machine. One water unit for the general range and one oil unit for the high-temperature material is the conventional answer. Alternatively, a dual temperature unit gives you one circuit that can heat and cool, which removes the changeover plumbing entirely.
Water type for standard temperatures and any colour-critical application. Oil type for temperatures above 120 °C and high-temperature polymers. Dual temperature when you need both heating and cooling from one unit. Tell us your material, temperature and cycle time, and we will specify the right unit — contact Zillion.